Shop
RZC-YAXZ3V-NA2XFGBY
Aluminium conductor power cable, XLPE insulation, steel tape armour (STA) and PVC sheath, rated 0.6/1 kV — for installations requiring robust protection.
RZC-YAXZ4V-NA2XBY
Aluminium conductor cable, XLPE insulation and filler, armour (double steel or double aluminium depending on core) plus PVC sheath, rated 0.6/1 kV.
RZC-YAXZ4V-NA2XBY
Aluminium conductor cable, XLPE insulation and filler, armour (double steel or double aluminium depending on core) plus PVC sheath, rated 0.6/1 kV.
RZC-YXCZ1-N2XCH
Halogen‑free copper conductor cable: CU conductor, XLPE insulation, SC (screen) layer, HFFR sheath. Voltage rating 0.6/1 kV. For standard industrial power networks where halogen‑free behaviour is required.
RZC-YXCZ1-N2XCH
Halogen‑free copper conductor cable: CU conductor, XLPE insulation, SC (screen) layer, HFFR sheath. Voltage rating 0.6/1 kV. For standard industrial power networks where halogen‑free behaviour is required.
RZC-YXZ1-N2XH
Copper conductor power cable, insulation XLPE, halogen‑free (HFFR) sheath system (no armour in standard version). Rated 0.6/1 kV. Developed for installations requiring halogen‑free behaviour and flame retardance (smoke density, low halogen) in fixed wiring.
RZC-YXZ1-N2XH
Copper conductor power cable, insulation XLPE, halogen‑free (HFFR) sheath system (no armour in standard version). Rated 0.6/1 kV. Developed for installations requiring halogen‑free behaviour and flame retardance (smoke density, low halogen) in fixed wiring.
RZC-YXZ1UV-N2XHUV
Halogen‑free copper conductor power cable: CU conductor, XLPE insulation, HFFR sheath, UV‑resistant outer jacket. Voltage rating 0.6/1 kV. Suitable for installations requiring fire‑safety and outdoor exposure.
RZC-YXZ1UV-N2XHUV
Halogen‑free copper conductor power cable: CU conductor, XLPE insulation, HFFR sheath, UV‑resistant outer jacket. Voltage rating 0.6/1 kV. Suitable for installations requiring fire‑safety and outdoor exposure.
RZC-YXZ2Z1-N2XRH
Halogen‑free copper conductor cable with steel wire armour: CU conductor, XLPE insulation, SWA (steel wire armour), HFFR sheath. Voltage rating 0.6/1 kV. Ideal for installations where mechanical protection is required (underground or heavy duty). ozlerkablo.com.tr
RZC-YXZ2Z1-N2XRH
Halogen‑free copper conductor cable with steel wire armour: CU conductor, XLPE insulation, SWA (steel wire armour), HFFR sheath. Voltage rating 0.6/1 kV. Ideal for installations where mechanical protection is required (underground or heavy duty). ozlerkablo.com.tr
RZC-YXZ4V-N2XBY
Copper conductor power cable with XLPE insulation, double armour steel tape (STA) or alternate “ATA” version in some variants, sheath PVC. Rated 0.6/1 kV. For heavy duty mechanical stress zones (power centres, industrial plants, under‐ground).